{"id":10386,"date":"2020-06-22T14:24:07","date_gmt":"2020-06-22T11:24:07","guid":{"rendered":"https:\/\/kyivguma.ua\/?p=10386"},"modified":"2022-09-12T16:12:27","modified_gmt":"2022-09-12T13:12:27","slug":"perchatky-rezynovye-dyelektrycheskye-rd-pro-katehoryy-r-c","status":"publish","type":"post","link":"https:\/\/kyivguma.ua\/en\/perchatky-rezynovye-dyelektrycheskye-rd-pro-katehoryy-r-c\/","title":{"rendered":"Dielectric rubber gloves RD Pro category R, C"},"content":{"rendered":"<p>DECLARATION OF CONFORMITY <strong><a href=\"https:\/\/kyivguma.ua\/wp-content\/uploads\/2022\/06\/Deklarats-Rukav-diel-kl-0_-1-_kat-R-C-trykotazh.pdf\">HERE<\/a><\/strong><\/p>\n<div class=\"container page-single__wrapper\">\n<div class=\"page-single__content\">\n<div class=\"page-single__text\">\n<p>USAGE INSTRUCTIONS<br \/>\nRubber dielectric gloves are electrically insulating individual protection means. They protect from current injury during live work. Depending on the work type the gloves range <strong>from class 00 till class 1, they are available in sizes 8, 9\u00a0 10, 11.<\/strong> The gloves comply with the requirements of the standard EN 420:2003+A1:2009, EN 60903:2003, \u0406\u0415\u0421 60903:2014, as well as the PPE Regulation 2016\/425 (Category III).<\/p>\n<p>CLASSIFICATION<br \/>\nChoose the required class and category (special properties) of gloves depending on the work type:<\/p>\n<table border=\"2\" width=\"621\">\n<tbody>\n<tr>\n<td width=\"75\">Code<\/td>\n<td width=\"76\">Class<\/td>\n<td width=\"77\">Category<\/td>\n<td width=\"213\">Maximal operating voltage for alternating current V<\/td>\n<td width=\"180\">Bearable testing voltage V<\/td>\n<\/tr>\n<tr>\n<td>DG.00.K.<\/td>\n<td>00<\/td>\n<td>\u0410<\/td>\n<td>500<\/td>\n<td>2500<\/td>\n<\/tr>\n<tr>\n<td>DG.0.K.<\/td>\n<td>0<\/td>\n<td>R, C<\/td>\n<td>1000<\/td>\n<td>5000<\/td>\n<\/tr>\n<tr>\n<td>DG.1.K.<\/td>\n<td>1<\/td>\n<td>R, C<\/td>\n<td>7500<\/td>\n<td>10000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Special \u0441haracteristics<\/p>\n<table border=\"2\">\n<tbody>\n<tr>\n<td>Category<\/td>\n<td>Resistant to<\/td>\n<\/tr>\n<tr>\n<td>\u0410<br \/>\n\u041d<br \/>\nZ<br \/>\nR<br \/>\nC<\/td>\n<td>Acid<br \/>\nOil<br \/>\nOzone<br \/>\nAcid, oil, ozone<br \/>\nExtremely low temperature<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">NOTE 1. Category R includes characteristics of categories A, H and Z.<br \/>\nNOTE 2. Any categories combination can be used.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>1.STORAGE<br \/>\nThe gloves in manufacturer\u2019s package shall be stored indoors at the temperature from +10 \u00ba\u0421 till +21 \u00b0\u0421 at the distance more than 1m from heating devices. In the process of storage the gloves shall be protected from mechanical factors (compression, bending), direct sunlight, artificial light, ozone source, water, oils, fats, petrol and other rubber damaging substances.<br \/>\nWarrantee period \u2013 1 year from the date of manufacture subject to storage and usage conditions.<\/p>\n<p>2.REVIEW BEFORE USAGE<br \/>\nBefore every usage the both gloves (a pair of gloves) shall be visually checked if they are clean and if there is a testing date indicated. The gloves shall be checked if they are not damaged and torn visually or by blowing them up with the air (if possible).<br \/>\nIt is prohibited to use: wet gloves (shall be dried); gloves with punctures, cuts and other mechanical damages as well as the gloves with the invalid testing period which have not been tested by the electricity during the last 6 months.<br \/>\nThe gloves manufactured more than 12 months prior to their first use shall be re-tested by the electricity before their usage.<\/p>\n<p>3.USAGE RESTRICTIONS<br \/>\nThe gloves shall be used at the temperature from minus 25 \u00b0 \u0421 till plus 55 \u00b0\u0421.<br \/>\n*Category \u0421 gloves shall be used at the environment temperature from minus 40\u00b0 \u0421 till plus 55 \u00b0\u0421.<br \/>\nThe gloves shall be protected from mechanical damage, heat or light, oil, water, petrol, dissolvents and other substances damaging the rubber.<\/p>\n<p>4.CLEANING<br \/>\nAfter the usage, if necessary, the gloves shall be washed with soapy water at the temperature not more than +40\u00ba\u0421 and cleaned\/wiped from dirt, oil, water, petrol and other rubber damaging substances. They shall be dried in ventilated room at the temperature not higher than +60\u00ba\u0421 as long as they are completely dry.<\/p>\n<p>5.PERIODICAL TESTING<br \/>\nBefore the periodical inspection and electrical re-testing the gloves shall be cleaned from dirt and completely dried.<br \/>\nThe class 1 gloves shall be tested for air keeping, visually checked if they are hermetically sealed. Afterwards the control dielectric testing shall be conducted according t\u043e IEC 60903:2014.<br \/>\nGloves testing period \u2013 1 time\/ 6 months.<br \/>\nThe damaged, non-hermetic gloves or gloves with negative electric test result shall be utilized in a way preventing their further usage.<br \/>\nDo not use the gloves stored without inspection more than 6 months. The manufacture date shall be considered to be the testing date.<br \/>\nSpecial exception for 00 and 0 class gloves:<br \/>\nVisual control and\/or hermetical sealing checking shall be sufficient to use these classes gloves stored under the required conditions. Control dielectric testing for the above mentioned gloves classes may be provided upon the owner\u2019s requirement.<\/p>\n<p>6.TRANSPORTATION<br \/>\nFor transportation use the manufacturer\u2019s original package.<br \/>\nThe upper load shall not exceed 5 kg.<br \/>\nAfter the transportation under the minus temperature the gloves shall be stored in the manufacturer\u2019s package for 24 hours indoors at the temperature from +10 \u00ba\u0421 till +21 \u00b0\u0421.<\/p>\n<p>7.DISPOSAL<br \/>\nUnused gloves shall be disposed as common domestic waste.<br \/>\nAfter the usage while contacting with chemicals the gloves shall be disposed according to the certain chemical requirements!<\/p>\n<p><strong><span style=\"font-family: georgia, palatino, serif; font-size: 14pt;\">Read the usage <a href=\"https:\/\/kyivguma.ua\/wp-content\/uploads\/2022\/06\/inctructia_engRD-Pro.pdf\">INSTRUCTIONS<\/a> carefully before the usage!<\/span><\/strong><\/p>\n<div class=\"gallery-container\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"gallery-container\"><img style=\"display: none !important;\" src=\"https:\/\/kyivguma.ua\/wp-content\/uploads\/2022\/06\/RDPro_class0.png\" alt=\"\" \/><img style=\"display: none !important;\" src=\"https:\/\/kyivguma.ua\/wp-content\/uploads\/2022\/06\/perchatka.png\" alt=\"\" \/><\/div>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>DECLARATION OF CONFORMITY HERE USAGE INSTRUCTIONS Rubber dielectric gloves are&#8230;<\/p>\n","protected":false},"author":1,"featured_media":10387,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[9],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/posts\/10386"}],"collection":[{"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/comments?post=10386"}],"version-history":[{"count":9,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/posts\/10386\/revisions"}],"predecessor-version":[{"id":10645,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/posts\/10386\/revisions\/10645"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/media\/10387"}],"wp:attachment":[{"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/media?parent=10386"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/categories?post=10386"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kyivguma.ua\/en\/wp-json\/wp\/v2\/tags?post=10386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}